Key takeaways
- Many H codes fix the signal word: H225, H301, H314 or H318 always mean Danger. A record that says Warning with one of them is wrong somewhere.
- Pictograms follow from the hazard codes, with precedence rules: the skull replaces the exclamation mark for acute toxicity, and corrosion replaces it for irritation.
- Four of the 15 text-based public SDSs we sampled printed hazard statements without H codes, which US rules allow. A checker must not treat that as an error.
Section 2 has to agree with itself#
The label elements in Section 2 (signal word, pictograms, hazard statements) all follow from the classification. That makes them cross-checkable. If an extracted record says "Warning" next to H225, either the extraction misread something or the document is inconsistent. Both are worth a person's minute before the data reaches a label printer.
Signal word against H codes#
Some hazard statements only ever come with Danger. Examples: H224 and H225 (extremely and highly flammable liquids), H300 and H301 (fatal and toxic if swallowed), H314 (severe skin burns), H318 (serious eye damage), H334 (respiratory sensitisation), H340, H350 and H360 (germ cell mutagenicity, carcinogenicity and reproductive toxicity, category 1). Others depend on the category: H228 is Danger for category 1 flammable solids and Warning for category 2. A safe rule:
- If any Danger-only code is present, the signal word must be Danger.
- If there are hazard codes that need a signal word and none is given, flag it.
- If the signal word is Danger but no code needs it, flag it as overstated.
Check translations too. Gefahr, Fara, Fare and Vaara mean Danger; Achtung, Varning, Advarsel and Varoitus mean Warning.
Pictograms against H codes#
Each pictogram follows from a set of hazard classes: GHS02 (flame) for flammables, GHS05 (corrosion) for H290, H314 and H318, GHS06 (skull) for acute toxicity categories 1 to 3, GHS08 (health hazard) for CMR, STOT and aspiration hazards. Two precedence rules matter. If the skull applies, the exclamation mark is not used for acute toxicity. If corrosion applies, it is not used for skin or eye irritation. Under US OSHA rules the environment pictogram (GHS09) is optional, so flag a missing GHS09 for information only.
Pictograms are images on the PDF, and some extractions return none at all. An empty list is more often "not captured" than "missing from the SDS", so report it at a lower severity than a list that is present but incomplete.
Flash point against flammability#
Section 9 and Section 2 have to agree on flammable liquids: a flash point below 23 °C goes with H224 or H225, 23 to 60 °C with H226. A liquid with a flash point of 40 °C and no flammability statement deserves a look. Parse the flash point carefully. SDSs write "ASTM D93: 65 °C" and "ISO 2719: 12 °C", and a naive parser reads the method number instead of the temperature.
What real SDSs do#
We ran these rules over 16 publicly available SDS PDFs. Four of the 15 documents with a text layer printed their hazard statements as text with no H codes ("Extremely flammable aerosol"). That is allowed in the US, but it means the signal word and pictogram checks have nothing to compare against. A good checker says so at info level instead of raising a false alarm. We changed ours to do exactly that after this test.
In the API#
These checks run on every SafetyDataSheetAPI extraction and appear in validation.issues with stable codes such as signal_word_mismatch, pictogram_missing, pictogram_unexpected and flash_point_unclassified. validation.status is review when there is at least one error or warning, so you can route on a single field. No AI is involved in the checks; they are rules over the extracted record.
Frequently asked questions
Can a record pass every check and still be wrong?
Yes. Consistent is not the same as correct. The checks catch contradictions and malformed values; they cannot tell whether the supplier classified the product correctly.
Which rule set do you follow, GHS, CLP or OSHA?
The signal word and pictogram rules are common to GHS, EU CLP and US HazCom. Where they differ, for example the optional environment pictogram under OSHA, the check reports information rather than an error.
Do you check P statements?
Codes are parsed and validated for format. Checking which P statements a classification requires is not done yet.